Parallel ABR (pABR)

Parallel ABR for Fast EP in SmartEP
Designed to save you time, SmartEP’s pABR is the fastest way to acquire ABRs by recording multiple ABRs in a single run. The module presents randomly timed sequences of stimuli, including clicks, tone bursts, or iChirp stimuli across multiple frequencies and/or intensity levels at the same time. Choose how the pABR stimuli are delivered from several presentation methods, including Random, Interleaved, or Screening.


How is that possible?
Parallel ABR (pABR) enables the simultaneous acquisition of responses to stimuli at multiple frequencies in both ears. While pABR uses the same fundamental stimulation and recording principles as traditional ABR, it leverages the frequency specificity and temporal characteristics of the peripheral auditory system to record multiple responses in a single run.
Our novel patent-pending Real-Time Multi-Vectorial Averaging Deconvolution (MVAD) technique separates overlapping responses to the stimuli sequences, allowing users to record and display up to 10 distinct ABR waveforms simultaneously during acquisition.
New ABR Response Plot!
The latest version of SmartEP includes an ABR response plot that automatically displays user-labeled wave V responses as a function of frequency and stimulation level, with stimulation levels expressed in nHL or eHL.


What can you do with pABR?
- Simultaneous acquisition of up to 5 frequencies per ear
- Test both ears simultaneously using air conduction
- Set any combination of intensity and frequency
- Stimulus options include clicks, tone bursts, or iChirps
- Test using air and bone conduction at 500, 1000, 2000, and 4000 Hz
- Choose from multiple methods: Random, Random Rate Limited, Interleaved, and Screening Protocol
- Stimulus presentation rates of up to 40/s
- Integrated objective response measures
- Real-Time MVAD technique (patent pending)
Why choose SmartEP’s pABR?
Because every minute in the clinic matters, especially for threshold ABRs in infants. pABR reduces your testing time without compromising the quality of your responses, allowing you to record more diagnostic information and reducing the need for repeat visits. You can test up to 5 frequencies or intensities at the same time. And the best part? You get all that in around 2 minutes per run. That’s 8 to 10 ABRs in 2 minutes!

Configure each of the 5 stimuli independently by frequency and intensity to fit the workflow you need:
- Frequency profile in minutes: Run all four standard audiometric frequencies (500, 1000, 2000, and 4000 Hz) simultaneously in both ears at the same intensity to acquire a frequency-specific ABR profile in as little as 2–3 minutes.
- Fast threshold search: Present a single stimulus type (click, tone burst, or iChirp) at multiple intensity levels simultaneously instead of stepping down one level at a time, which can significantly shorten threshold searches.
- Test up to 5 frequencies or intensities simultaneously per ear
- Approximately 2 minutes per intensity
- High-quality waveforms with morphology comparable to standard ABR
- Simultaneous cross-frequency masking improves place specificity

The intensity series displayed above was acquired in under 4 minutes

The frequency series displayed above was acquired in under 4 minutes
Parallel ABR is available on the following devices
The pABR module is compatible with Duet and Aria systems. Existing Duet and Aria customers using SmartEP can upgrade to pABR.